Dear Community Members, Please help to set up the alerts as following: Interface down: if 1 tunnel is down in a device, open a P3, if both tunnels are down, open a P2
I'm facing issue configuring reliable alert when Cisco switch power supply status changes. The way i set it is working and i'm getting alert with all relevant to issue data. The problem is when condition - power supply status = shutdown is triggered on single unit. Solawinds sends alerts for all nodes assigned this puller.…
Hello, I am looking for report which show me what all alerts associated with each node/objects. Can anyone help me with the query how to get these details from DB? Manage to create below query but not showing all alerts assosicated with nodes. Some alerts are missing. Even in alert object some alertID are missing. SELECT…
We have a lot of alert actions, over 1,000 Many are duplicates / orphans that have added up over the years. Is there a query to find the alert actions that are not assigned to any alerts? This will allow me to start removing them. Thank you
Hi - I'm trying to set up device status alerts for printers based on the printer alert description MIB. MIB Value Type = Raw Value, and SNMP Get Type = GET TABLE (to get all the row ID values). The problem is, I can't seem to fetch all values from UDP to the alert trigger condition. Alert only works for specific Row ID,…
I've been asked to investigate the impact of changing the trigger wait time on our alerts. Currently we have alerts trigger after the trigger conditions have been met for 10 minutes. Is there a SWQL query I can run to get a view of how many alerts would have been generated in the past week if we had lower trigger wait…
Hello team, There was a person who managed SolarWinds at my workplace and they have been let go. The issue is that their user account has several dashboards in production that are used to monitor services. Now that they no longer work at the institution, we want to delete their user account, but first, we want to identify…
Configuring alerts for applications on servers and the time when the servers reboots to suppress the alarm. This works fine. But during testing. I disable a service during this window but after the window passes never get a email alert for the down service. Is there a way to have this retrigger so alerts for down services…
Hello, I need help setting up an alert for the existence of the file. I have the application monitoring working, but I need help setting up the alert for email. I have added the components name file existence in alert but cant find where it says to trigger Files exists File does not exist