Currently it's not possible to use any verification the SSL cert used by Orion on the SWIS API port (tcp/17778) due to it being a self-signed SSL cert with a CN of SolarWinds-Orion on all of the pollers in the solution (see Enabling SSL Certificate Verification for the SDK). This means that verification of the SSL…
Looks like Cisco has done enough changes in the MIB structures that they have adopted specially on the newer platforms that they have launched. Nexus family of switches now do not use the traditional MIB's. For example, the earlier devices used to support the OID 1.3.6.1.3.60.1.1.1 for ipMRouteEnable but now the latest…
it would be great if an export option is available in All Active Alerts page. It makes easier to export the active alerts. Thanks, DN
Hello SolarWinds NPM Product Management team, Greetings! I am SolarWinds NPM admin for my organization, There have been multiple request which comes to me for scheduled muting of alerts, since we only have Scheduled Unmanage utility I am communicating to the requestors that we cannot mute the alerts in a periodic way. The…
Dear SolarWinds, I think I saw this request in the past, but I could not find it. We really like the old Network Atlas link utilization and we would like to have the option to use it in new Orion Maps. Currently Orion Maps can change the color of the link only when it reaches a threshold, which is very limiting (only two…
I submitted a feature request to couple the snmp trap editor from the engineer's toolset to the NPM webconsole and tightly integrate it so that when adding varbinds swis variables could be selected. We send traps from NPM to our alarm management system and it would be nice to be able to define trap templates for…
Currently we are not able to get CPU, Memory, and OS version data out of our Nokia (formerly Alcatel) gear. It would be really nice to have these things show up. The firmware release currently shows up as unknown, and it shows zero CPUs. CPU and memory are not graphed.
Hello: Velocloud devices interface use RX and TX is not implemented, the data is faulty on the NPM. The correct OIDS (object no interface) are: 1.3.6.1.4.1.45346.1.1.2.3.2.2.1.38 1.3.6.1.4.1.45346.1.1.2.3.2.2.1.39 I think this is mandatory since velocloud is a bug player in SD-WAN. Also NTA does not work as…
I would like a comment field to pop up when someone tries to unmanage or mute a node. It would be nice if the NPM admin could set the field to be optional or required; and be able to edit the text indicating what to put in the field. Reason for the request: We have some devices that have been unmanaged for a long time --…
Hi All, If someone has already raised this as a feature request in the past, please ignore the same. There should be an option to just add the nodes as 'ICMP' along with 'WMI' & 'SNMP' under Preferred Polling Method. Why waste cycles and delay the discovery when you don't want to check if end devices are compatible with…
It looks like you're new here. Sign in or register to get started.