Get the latest news about SolarWinds NetFlow Traffic Analyzer (NTA)
Is it possible to monitor traffic with NTA on a Cisco Nexus 9000? Ive found info on a Cisco forum which states Netflow is not supported. Is there any workaround for this type of device? Heres some info about my device... 9372-100# sh ver Cisco Nexus Operating System (NX-OS) Software Software BIOS: version 07.17 NXOS:…
Below is the config that I am using for a cisco 3850 L3 switch. Does anyone notice anything out of the ordinary? I have only recently hired on at this establishment and this is something that hasn't worked in a few years. So, I'm trying to eliminate things to better get an idea of what the hold up is. *** flow record…
Hi Guys, We are a Managed Service Provider with 150+ customers and ~12000 devices monitored via our Orion platform (2017.1.3 SP3, NTA 4.2.2). As our customers all have their own networks that clash we apply NAT'ing to their IP's in order to manage them. This in turn means that DNS or NetBIOS lookup will not work for any of…
Gigamon is courting my server and security teams, to provide Netflow based monitoring, specifically for tracking security events & flows. If you have any experience using that brand of equipment, or with Netflow for security, in parallel with NTA, I'd love to have your thoughts. Rick Schroeder
I have tried with one of the sql query but its getting error. If possible provide me the new sql query for percent utilization in 95th percentile as percentag for every week and month. it would be great help for me to resolve the issue from my end.
I can set the NTA 'Charting and Graphing Settings' to display the last 5 minutes of Netflow data but I cant seem to do the same with my sql statement. i.e. my sql statement only works if my time range is the past hour or more. The table i'm querying Is 'Orion.Netflow.Flowsbyconversation' so maybe that does not hold current…
Hi I'm trying to configure NTA on Cisco 2960C with no luck. Is there any specific configuration needed for this model ? It seems to support Netflow as I'm able to run all commands with no issue provided here as a sample, But for some reasons it's not showing up in NTA interfaces. Cisco 2900 series routers sample…
Hello and Good day Is there anyway we can find out which node/interface is causing these Application component monitors to go critical in SAM (latest version) Packet Dropped: Unmonitored Node - 4.3 million Unmonitored Interface - 3534 Thank you
Thank you
I am attempting to build a report showing the total bytes transferred by port for the "unmonitored" application for the last 12 hours. I would like to show Ingress, Egress and Total Bytes for each port. However, I get the following error when I ad columns to the report: Any ideas what I need to do?
It looks like you're new here. Sign in or register to get started.