cancel
Showing results for 
Search instead for 
Did you mean: 
Create Post
Highlighted
Level 11

SNMP Request for EMC CLARiiON Storage

Jump to solution

According to available documentation EMC has developed SNMP support utilizing OID. 1.3.6.1.4.1.1981
The latest SolarWinds MIB database does not include the 1981 tree.


-------------------------------------------------------------------


One reference document found was located on a DELL site.
https://dcse.dell.com/SelfStudy/Assoc_Server_Versions/server_9_self_study/ita80/documents/H537_3_man...


 


One other extract demonstrated.



MIB File: clariion_fsc_2.mib


MIB Module: CLARIION-MIB
clarInfo
clariion
deviceID
deviceType
eventID
eventMonitor
eventMonitorTrap
eventMonitorTrap_Error
eventMonitorTrap_Fault
eventMonitorTrap_Info
eventMonitorTrap_Warn
eventText
hostName
storageSystem
.1.3.6.1.4.1.1981
.1.3.6.1.4.1.1981.1
.1.3.6.1.4.1.1981.1.1
.1.3.6.1.4.1.1981.1.4
.1.3.6.1.4.1.1981.1.4.3
.1.3.6.1.4.1.1981.1.4.4
.1.3.6.1.4.1.1981.1.4.5
.1.3.6.1.4.1.1981.1.4.6
.1.3.6.1.4.1.1981.1.4.7
.1.3.6.1.4.1.1981.2
.1.3.6.1.4.1.1981.0.2
.1.3.6.1.4.1.1981.0.0.2
.1.3.6.1.4.1.1981.3
.1.3.6.1.4.1.1981.0.3
.1.3.6.1.4.1.1981.0.0.3
.1.3.6.1.4.1.1981.4
.1.3.6.1.4.1.1981.0.4
.1.3.6.1.4.1.1981.0.0.4
.1.3.6.1.4.1.1981.5
.1.3.6.1.4.1.1981.0.5
.1.3.6.1.4.1.1981.0.0.5
.1.3.6.1.4.1.1981.6
.1.3.6.1.4.1.1981.0.6
.1.3.6.1.4.1.1981.0.0.6
enterprises.1981
enterprises.1981.1
enterprises.1981.1.1
enterprises.1981.1.4
enterprises.1981.1.4.3
enterprises.1981.1.4.4
enterprises.1981.1.4.5
enterprises.1981.1.4.6
enterprises.1981.1.4.7
enterprises.1981.2
enterprises.1981.0.2
enterprises.1981.0.0.2
enterprises.1981.3
enterprises.1981.0.3
enterprises.1981.0.0.3
enterprises.1981.4
enterprises.1981.0.4
enterprises.1981.0.0.4
enterprises.1981.5
enterprises.1981.0.5
enterprises.1981.0.0.5
enterprises.1981.6
enterprises.1981.0.6
enterprises.1981.0.0.6


 -----------



***** SNMP QUERY STARTED *****
1: sysDescr.0 (octet string) CX300 - Flare 2.19.0.300.4.002
2: sysObjectID.0 (object identifier) deviceType
3: sysUpTime.0 (timeticks) 0 days 00h:03m:05s.65th (18565)
4: sysContact.0 (octet string) (zero-length)
5: sysName.0 (octet string) CX300_112_113
6: sysLocation.0 (octet string) (zero-length)
7: sysServices.0 (integer) 72
8: ifNumber.0 (integer) 2
9: ifIndex.1 (integer) 1
10: ifIndex.2 (integer) 2
11: ifDescr.1 (octet string) Internal loopback interface for 127.0.0 network
12: ifDescr.2 (octet string) Intel(R) 8255xER PCI Adapter - Packet Scheduler Miniport
13: ifType.1 (integer) softwareLoopback(24)
14: ifType.2 (integer) ethernet-csmacd(6)
15: ifMtu.1 (integer) 32768
16: ifMtu.2 (integer) 1500
17: ifSpeed.1 (gauge) 10000000
18: ifSpeed.2 (gauge) 100000000
19: ifPhysAddress.1 (octet string) (zero-length)
20: ifPhysAddress.2 (octet string) 00.60.16.00.32.86 (hex)
21: ifAdminStatus.1 (integer) up(1)
22: ifAdminStatus.2 (integer) up(1)
23: ifOperStatus.1 (integer) 5
24: ifOperStatus.2 (integer) 5
25: ifLastChange.1 (timeticks) 0 days 00h:00m:00s.00th (0)
26: ifLastChange.2 (timeticks) 128 days 03h:00m:14s.53th (1107001453)
27: ifInOctets.1 (counter) 0
28: ifInOctets.2 (counter) 252057891
29: ifInUcastPkts.1 (counter) 0
30: ifInUcastPkts.2 (counter) 733588
31: ifInNUcastPkts.1 (counter) 0
32: ifInNUcastPkts.2 (counter) 596297
33: ifInDiscards.1 (counter) 0
34: ifInDiscards.2 (counter) 0
35: ifInErrors.1 (counter) 0
36: ifInErrors.2 (counter) 0
37: ifInUnknownProtos.1 (counter) 0
38: ifInUnknownProtos.2 (counter) 3
39: ifOutOctets.1 (counter) 0
40: ifOutOctets.2 (counter) 686169046
41: ifOutUcastPkts.1 (counter) 0
42: ifOutUcastPkts.2 (counter) 921561
43: ifOutNUcastPkts.1 (counter) 0
44: ifOutNUcastPkts.2 (counter) 2127
45: ifOutDiscards.1 (counter) 0
46: ifOutDiscards.2 (counter) 0
47: ifOutErrors.1 (counter) 0
48: ifOutErrors.2 (counter) 0
49: ifOutQLen.1 (gauge) 0
50: ifOutQLen.2 (gauge) 0
51: ifSpecific.1 (object identifier) (null-oid) null
52: ifSpecific.2 (object identifier) (null-oid) null
53: ipForwarding.0 (integer) not-forwarding(2)
54: ipDefaultTTL.0 (integer) 128
55: ipInReceives.0 (counter) 1915926
56: ipInHdrErrors.0 (counter) 0
57: ipInAddrErrors.0 (counter) 234595
58: ipForwDatagrams.0 (counter) 0

0 Kudos
1 Solution

Accepted Solutions
Highlighted
Level 15

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

Hi everyone on this thread - we are working on a new free tool that is focused on EMC Clariion. If you would be interested in trying it out or just hearing more - please email me at christine.bentsen@solarwinds.com. 

--Christine

View solution in original post

0 Kudos
22 Replies
Highlighted
Level 11

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

 


Will Solarwinds be adding in support of .1.3.6.1.4.1.1981?

0 Kudos
Highlighted
Level 19

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution
Will Solarwinds be adding in support of .1.3.6.1.4.1.1981?
 

Support how?  What are you looking for?  Is it something the Universal Device Poller  can't monitor?

0 Kudos
Level 10

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

 1.3.6.1.4.1.1981 (dataGeneral) IS compiled into the Orion MIB database. Tricky part is getting your EMC to respond to SNMP, not the other way around. We have yet to get ours setup, but for when we do, Orion is ready.

 

You will want to try your luck using 1.3.1.6.2.1.75  and 1.3.6.1.4.1.1139 also.


 

0 Kudos
Highlighted
Level 11

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

Having recently upgrade the engineer's toolset, Orion, and Cirrus to the latest releases I wrongly A$$umed that we would have the latest.  Not so Charley Brown.  After downloading the "Orion MIB" and adding to three different locations (ugh!) I was able to browse the cLARiiOn.  It is really functionally limited.


Need more testing.

0 Kudos
Highlighted
Level 7

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

Bump. Has any progress been made with the EMC Clariion monitoring?

0 Kudos
Highlighted
Level 7

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

rcahill or someone able to monitor Clariion through solarwinds ????

0 Kudos
Highlighted
Level 19

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

Specifically, what info do you want to collect?

0 Kudos
Highlighted
Level 7

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

What ever i can, at this moment i can poll anything 😞

0 Kudos
Highlighted
Level 7

Re: SNMP Request for EMC CLARiiON Storage

Jump to solution

Whatever i can , at this moment i cannot pull anything from clariion. I dont want to set the trap and monitor that

0 Kudos