Hi
Yesterday we did the power down alert activity on devices having dual power supply , just removing the one power cord . Result are below
1 :Got power down alert mail from solarwinds for routers ( ASR1001-X & ISR4451-X ) .
2: Not received power alert mail from solarwinds for Switches ( WS-C3850-24S ) . Devices neither show in waring & critical alert in solarwinds .
Note : -We have already configure the SNMP traps below on switches so that alerts can be configured using traps but that also failed.
snmp-server enable traps envmon an shutdown supply temperature status
location | Devcie IP | Hostname | Device Type | Device Model | Alert Mail Received from solarwinds |
RCC Vadodara | RCC_VDR_ISR_SEC_R201 | Router | ISR4451-X/K9 | Yes | |
RCC Vadodara | RCC_VDR_L3_CORE_SEC_R201 | Switch | WS-C3850-24S | No , wait 20 minute , no power down alert received | |
RCC Mohali | RCC_MHL_ASR-SEC | Router | ASR1001-X | Yes , Power down alert mail received after 10 minute | |
RCC Mohali | RCC_MHL_CORE-SEC | Switch | WS-C3850-24S | No , wait 20 minute , no power down alert received | |
RVC Kolkata | RVC_KOL_ISR_SEC_R201 | Router | ISR4451-X/K9 | Yes , Power down alert mail received after 10 minute | |
RVC Kolkata | RVC_KOL_L3_CORE_SEC_R201 | Switch | WS-C3850-24S | No , wait 20 minute , no power down alert received |